801R Software upgrade procedure
As part of our effort to continuously improve our
products we have sent you new software for your 801R system. There are
several enhancements in version 1.4 which make the 801R generally easier
to use, especially for multi-preamplifier systems. As always, we would
love to hear your comments and suggestions.
SOFTWARE CHANGES IN VERSION 1.4:
Please read the revised operators manual for detailed
information on these features.
-
Add 24 ch meter mode to RCU: Pressing the MODE button
toggles between 8 channel setup mode and meter mode. Pressing the MODE
button for 2 seconds enters the preamp setup mode.
-
Eliminate peak indicator. Replace peak indicator with
peak hold on bargraph meters. Option for no peak hold, decay peak hold
and infinite peak hold.
-
Group information is now stored with presets.
-
Number of preset registers increased to 99.
-
Preset 0 is now enabled. This is the null setup preset
that can be recalled but not written over. Null setup is: all gain settings
to minimum, +48V off, Phase off, no groups defined.
-
Enable Global preset store and recall function from
remote.
-
Preset store and recall menus are now separated for
clarity.
-
Store and recall functions are now confirmed.
This document outlines the procedure for
upgrading the software in the 801R preamplifier and the remote control
unit (RCU). Please contact your dealer or the Grace Design factory if you
do not feel fully comfortable with performing this procedure.
NOTE: The supplied PROM chips are
CMOS devices and are static sensitive. Care should be taken to avoid static
electricity buildup when performing this procedure.
TOOLS NEEDED:
-
IC puller
-
Small flat screwdriver
PREAMPLIFIER SOFTWARE REPLACEMENT:
-
Remove 9 screws from the top cover with the 3/32" hex
wrench and remove top cover.
-
With the preamplifier front panel towards you, locate
the digital control pcb located on the right hand side panel. Touch the
preamplifier chassis to dissipate any static electricity.
-
Locate U6 (see diagram on next page) and remove it by
gently prying the IC out of its socket with the small screwdriver.
-
Install the new preamplifier PROM in the socket. The
preamplifier PROM is labeled P1.4 Be very careful to install the new IC
in the proper orientation. The notched end of the IC should be up.
-
Inspect you work to verify that all of the IC pins are
in the socket and that the IC is oriented correctly.
Replace cover and install screws.
REMOTE CONTROL UNIT SOFTWARE REPLACEMENT:
-
Turn the RCU upside down and locate the four flat head
hex screws on the bottom side. Remove these four screws with the 3/32"
hex wrench. Turn the RCU on its side and let the top panel come away from
the box. Separate the top panel and the box as much as possible without
stressing the wires connecting the two halves.
-
Using the IC puller, remove U6. Use a gentile side to
side rocking motion to work the IC out.
-
Install the new RCU PROM in the socket. The RCU PROM
is labeled R1.4. Be very careful to install the new IC in the proper orientation.
-
Inspect you work to verify that all of the IC pins are
in the socket and that the IC is oriented correctly.
-
Carefully replace the top panel being sure that none
of the wires are pinched between the top panel and the box
-
Replace the four screws